PROFINET IO Device The interface. Start the device, write to Q and read from I, view the operating status, and run diagnostics.

This product is designed SDK exclusively for this purpose PROFINET IO Deviceand does not provide interfaces for other fieldbus protocols.

Class Structure​

PnSService                                       # Device instance
│
├── process_data → ProcessData # Write Q / read I
│ ├── inputs_mapping / outputs_mapping # Map once
│ ├── read_struct / write_struct # Snapshot, value does not change by itself
│ ├── In # Read I (module input), read-only
│ └── Out # Write Q (module output), writable
├── events → PnSEvents # Operating state events
│ ├── add_connected_changed # Cyclic exchange on/off
│ ├── add_state_changed # Operating state change
│ ├── add_error_occurred # Runtime error
│ └── add_logged # Each event above also logs this
├── diagnostics → PnSDiagnostics # Diagnostics sub-object (snapshot / IOPS / alarms / records)
│ ├── snapshot # Diagnostics snapshot
│ ├── io_status # IOPS / IOCS
│ ├── alarms / alarm_history # Local alarms / history
│ └── records # User area records
│
├── connected / state / wait_reason # Cyclic exchange / operating state / wait reason
├── ever_connected / error_code # Ever connected / runtime error
└── im_data # I&M identifier

Write Q (module output, device → controller), read I (module input, controller → device). The "flat" attribute diag_snapshot / is still alarms available and corresponds to diagnostics the same data.

Usage​

Start-Stop​

from darra_pns import PnSService, PnSErr

with PnSService() as svc:
rc = svc.start()
if rc != PnSErr.OK:
return

while running:
if not svc.connected:
# svc.wait_reason
continue
svc.write_bool("Q0.0", True) # Write Q
from_plc = svc.read_bool("I0.0") # Read I

svc.stop()

You don't need an example to see the state: PnSService.is_service_ready / PnSService.service_connected / PnSService.service_wait_reason.

Process Data​

MethodVisitNote
Process Datasvc.process_data.inputs_mapping(S) / outputs_mapping(S)Map once
Process Datasvc.process_dataSnapshot read_struct / write_struct, In / Out bytes

Identification​

name = svc.im_data.station_name
vendor = svc.im_data.vendor_id
product = svc.im_data.device_id

Reading and Writing Process Data​

Word and double-word types are big-endian.

The "Golden Path" involves a single mapping: when the source changes, the field changes accordingly (structures must be used _pack_ = 1).

import ctypes

class FromPlc(ctypes.BigEndianStructure):
_pack_ = 1
_fields_ = [("a", ctypes.c_uint8),
("b", ctypes.c_int16),
("flag", ctypes.c_uint8)]

# Map once
inp = svc.process_data.inputs_mapping(FromPlc)
outp = svc.process_data.outputs_mapping(FromPlc)
present = inp.a # It changes on its own after the bus is refreshed
outp.a = 1 # Video of the Direct Drop Process

# Snapshot: It won't change on its own after you copy it out
status, pos = svc.process_data.read_struct("Hi")
svc.process_data.write_struct("Hi", 1, -2)

svc.process_data.Out[0].content = 0x11
v = svc.process_data.In[0].content

Diagnostics and Alarms​

Through diagnostic reading svc.diagnostics (read-only snapshots: links, frame count, watchdog, jitter, and alarm monitoring).

snap = svc.diagnostics.snapshot
if not snap.ok:
print(snap.message)

for a in svc.diagnostics.alarms:
print(a.message)