Attributes and State Machines

Properties​

CategoryPropertyTypeAccessDescription
Staticis_service_ready / PnSService.is_service_readyboolread-onlyWhether the local service is ready
last_error / PnSService.last_errorstrread-onlyMessage describing the most recent failure across the entire application (sticky; not cleared upon success)
last_error_code / PnSService.last_error_codePnSErrread-onlyThe fault code from the most recent failed call across the entire application. Never fails; returns OK
service_connected / PnSService.service_connectedboolread-onlyWhether the IO controller is performing cyclic exchange. If the service is not started, this is False.
service_state / PnSService.service_statePnSStateRead-onlyOperational ST. If the service is not RUN = UNKNOWN
service_wait_reason / PnSService.service_wait_reasonstrread-onlyReason for the wait. Service did not start = 'Service not ready'
service_status_message / PnSService.service_status_messagestrread-onlyST message. If the service hasn't started = 'Service not ready'
Connections and Sessionsconnectedboolread-onlyWhether the IO controller has established cyclic data exchange. Only True means cyclic data is being exchanged
attachedboolread-onlyWhether this SDK session is connected to the local service. 'stop' does not change this value
is_running / is_startedboolread-onlyWhether the IO device is enabled (after start, before stop)
Operational STstatePnSStateread-onlyEnumeration of operational states. If the actual ST cannot be read, it is UNKNOWN; do not treat it as NONE
wait_reasonstrread-onlyReason for this session's wait. Empty when the IO controller is connected
ever_connectedboolread-onlyWhether a link has ever been established with the IO controller. True and connected is False = disconnected
fault Codeserror_codePnSRuntimeErrorCoderead-onlyLast runtime fault. Unrecognized negative value UNKNOWN; positive values are mapped to WIN32_ERROR
error_code_rawintread-onlyRaw value of the runtime fault (0 = no fault). Unrecognized values are still passed through this property
error_messagestrread-onlyRuntime fault message in Chinese
last_service_errorstrread-onlyThe most recent fault message for this session (sticky; not cleared upon success)
Byte-Level Operationsinputbytesread-onlyReads the entire block back; the name is reversed — it corresponds to the `process_data.Out` block; see the explanation below
outputbytesread-onlyA snapshot of the entire block; the name is reversed — it corresponds to the `process_data.In` block and shares the same source as read()
output_committedboolread-onlyWhether the written block has been sent out (written and delivered). Q never written / delivery failed = False
input / output The name is reversed

svc.input and svc.output the nameThe exact opposite of that set process_data:

PropertiesWhich part of the process data does this correspond to?
svc.inputand process_data.Out / outputs_mapping(S) The same piece(Not that one In )
svc.outputand process_data.In / inputs_mapping(S) The same piece(Not that one Out )

Don't use these in everyday writing: svc.read() / svc.write() and process_data.In / have the same Out names and meanings as the characters in the table above, so use those instead. Use svc.input / only when you need to write a whole paragraph of raw bytes svc.output; be sure to check the table above before using it.

Module functions are equivalent to class properties (class properties do not use parentheses). If the service hasn't been implemented yet last_error, no exception is thrown.

from darra_pns import (
is_service_ready, service_connected, service_state,
service_wait_reason, last_error,
)

ready = is_service_ready()
ctrl = service_connected()
st = service_state()
wait = service_wait_reason()
err = last_error()
PnSState

The link and data exchange ST between the device and the IO controller (return values of state / service_state).

class PnSState(IntEnum):
NONE = 0 # Not Initialized / Stack Not Initialized
IDLE = 1 # Started, waiting for the IO controller (no AR)
CONNECTING = 2 # The controller has initiated a link (STARTUP)
PARAMETERIZED = 3 # Parameterization complete (PRMEND), waiting for the application to be ready
APPLICATION_READY = 4 # Application Ready (APPLRDY), parameter exchange complete
DATA_EXCHANGE = 5 # Cyclic data exchange is normal (DATA)
ABORTED = 6 # link lost (ABORT)
RESETTING = 7 # Device is resetting (reserved ST name; this ST is not generated during a reset in the current version)
CONFIG_ERROR = 8 # Configuration Error Downgrade ST: ST can be queried, but process data exchange has not been started
UNKNOWN = 0x7FFFFFFF # Unknown / Unable to read the actual ST
  • Only DATA_EXCHANGE indicates that periodic data is being exchanged.
  • UNKNOWN "Unknown" / The actual ST cannot be read; do not treat it as NONE.
PnSRuntimeErrorCode

Enumeration of server-side runtime errors (as revealed by ST queries errorCode) anderror_code their return values.

class PnSRuntimeErrorCode(IntEnum):
OK = 0 # No errors
ERR_INIT = -1 # Stack initialization failed
ERR_CFG = -2 # Invalid configuration
ERR_THREAD = -3 # Failed to create a periodic thread / set priority
ERR_RUNNING = -4 # Invalid ST (repeated start/stop)
ERR_PDI = -5 # Process Data Exchange Failed
ERR_DAP = -6 # Insertion into slot 0 (DAP) failed
ERR_NULL = -8 # The device has not started (not started or has STOP)
ERR_DIAG = -9 # Invalid diagnostic parameter
WIN32_ERROR = 1 # System fault codes returned by the demoted ST (positive codes, such as 2048)
UNKNOWN = -10000 # Unrecognized value
  • Call Return Codes PnSErr The meanings are different; they should not be used interchangeably.
  • Unrecognized negative values are assigned to UNKNOWN, positive values to ; WIN32_ERROR the original values are passed through error_code_raw as-is via .
PnSErr Enumeration Values

SDK The return value of a call (start/stop, read/write process data, or diagnostics); 0 = success.

class PnSErr(IntEnum):
OK = 0 # Success
INVALID_PARAM = 1 # Invalid parameter
NOT_INITIALIZED = 2 # Device not initialized (not started)
ALREADY_INITIALIZED = 3 # The device has been initialized.
TIMEOUT = 4 # Operation timed out
NO_DEVICE = 5 # No available devices / Service unavailable
NOT_AVAILABLE = 6 # Feature Unavailable
IO_ERROR = 7 # IO Read/Write fault
ALARM_ERROR = 8 # fault Report
CONFIG_ERROR = 9 # Configuration Error
DLL_NOT_FOUND = 100 # Library not found
UNKNOWN = 999 # Unknown fault
  • This enumeration does not have a "Busy" member: returns whenstart() the real-time link port is occupied by another instance NOT_AVAILABLE.

Start-Stop​

start Once; do not call it every cycle.

start()​

def start(self) -> PnSErr

Enable IO: start the local service, establish a process data channel, POST /api/start. If start has already been called and stop has not, returns idempotently with PnSErr.OK.

This does not mean that the IO controller has completed cyclic exchange; whether the IO controller is exchanging data is shown by connected. Only one real-time session is allowed at a time; a second one returns PnSErr.NOT_AVAILABLE.

Example:

rc = svc.start()
if rc != PnSErr.OK:
print(svc.last_service_error)

stop()​

def stop(self) -> None

Deactivate IO (POST /api/stop). The process data channels and sessions are retained and can be started again with start. It is idempotent whether called before start or after stop. It is not close.

Example:

svc.stop()

close()​

def close(self) -> None

Terminate the service session on this machine. Q is cleared (only the data area); I is retained for the next program. Idempotent; with exits the call stack and returns to this method. Once released, this instance can no longer be used and must be re-initialized PnSService(). The real-time main path also releases the real-time link gate.

Example:

svc.close()

Operating State​

state​

Operational ST (Read-Only). start / stop Only enable / disable IO devices; this property is always read exactly as it appears on-site. If the actual ST cannot be read UNKNOWN, do not interpret it as NONE.

@property
def state(self) -> PnSState

Example:

if svc.state == PnSState.DATA_EXCHANGE:
print("周期数据交换正常")

wait_reason​

@property
def wait_reason(self) -> str

Reason for this session's wait. Empty when the IO controller is connected. In the if not svc.connected loop, read this property or last_service_error.

Example:

if not svc.connected:
print(svc.wait_reason)

ever_connected​

@property
def ever_connected(self) -> bool

Has a link ever been established with the IO controller? False = Never connected; True and connected == False = Disconnected. This determination remains in effect even after the link is lost.

Example:

if not svc.connected and svc.ever_connected:
print("掉线")

Error Code​

error_code​

@property
def error_code(self) -> PnSRuntimeErrorCode

Last runtime fault (enumeration). Unrecognized negative value UNKNOWN; positive values are returned WIN32_ERROR. The original value is still passed error_code_raw through. Use for Chinese messages error_message.

Example:

err = svc.error_code
text = svc.error_message
raw = svc.error_code_raw

error_code_raw​

@property
def error_code_raw(self) -> int

Original value of the runtime fault (0 = no fault). Unrecognized values are still passed through this property.

Example:

raw = svc.error_code_raw

error_message​

@property
def error_message(self) -> str

Chinese fault messages. Return a description with the original value for unrecognized codes; do not discard the information.

Example:

print(svc.error_message)

last_service_error​

@property
def last_service_error(self) -> str

The most recent failed script for this session (sticky). The success path is not cleared. If this if not connected property is empty during a loop, read it wait_reason.

Example:

print(svc.last_service_error)

Diagnosis​

Diagnostic subobjects diagnostics, as well as flat properties that read the same data. When RUN the program, check this section first before working with process data.

CategoryPropertyTypeAccessDescription
EntrydiagnosticsPnSDiagnosticsread-onlyDiagnostics subobjects (snapshots / IOPS / alerts / logs)
diag_snapshotPnSServiceDiagSnapshotread-onlyDiagnostic snapshot.
io_statusPnSServiceIoStatusRead-onlyIOPS / IOCS.`0x80` = GOOD.
alarms / alarm_historylistread-onlyActive alarms / History (last 500 entries). An empty array does not indicate a failure
alarm_count / critical_alarm_countintread-onlyTotal number of active alarms / Number of critical alarms. Same source as 'alarms'
im_dataPnSServiceImDataread-onlyI&M identifier: station name, manufacturer / equipment ID, order number
process_dataProcessDataread-onlyProcess data view; write Q / read I.

Example:

snap = svc.diag_snapshot
if not snap.ok:
print(snap.message)
else:
print("Up" if snap.link_up else "Down")

for a in svc.alarms:
print(a.message)

IOPS It depends— svc.io_status.all_good just because the value is there doesn't mean this beat will work.

Complete Example​

from darra_pns import PnSErr, PnSService

with PnSService() as svc:
rc = svc.start()
if rc != PnSErr.OK:
print(svc.last_service_error)
else:
while running:
if not svc.connected:
print(svc.state)
print(svc.wait_reason)
print(svc.error_message)
continue

svc.write_bool("Q0.0", True) # Write Q
from_plc = svc.read_bool("I0.0") # Read I
_ = from_plc

svc.stop()