Glossary
A Chinese-English glossary of PROFINET terminology and product-specific terms appearing in the "Darra Profinet IO Device Version History, Installation, and Configuration" section, with definitions based on their intended meanings.
Glossary
| Chinese | English | Note |
|---|---|---|
| IO Equipment | IO Device | A device that reads and writes data to the controller on-site. This product is a IO device (IO Device). |
| IO Controller | IO Controller | The IO Controller that periodically reads and writes IO data to multiple devices; this typically refers to the PLC serving as the IO Controller in an engineering system. This product is not a IO controller; see the Soft PLC section for more information. Darra Software PLC. |
| PROFINET | PROFINET | Name of the industrial Ethernet protocol. This product uses this protocol to exchange process data with the controller. |
| GSDML | GSDML | Device description file; used by the engineering configuration to add devices to the project. Can be exported using the configuration tool. |
| TIA Portal | TIA Portal | Siemens engineering configuration software,V15 as well as other software capable of importing files exported by this product GSDML. |
| RT Class 1 | RT Class 1 | This product supports real-time levels; periodic process data is routed through the real-time channel. No further action is required IRT. |
| IRT | IRT | Isochronous synchronization is a stricter real-time level that requires clock synchronization. This product does not support it. |
| PTCP | PTCP | PROFINET's clock synchronization mechanism,IRT which is used to synchronize the clocks of various devices. This product does not support it. |
| AR | Application Relationship | An application relationship is established between the controller and the device; periodic data exchange begins only after this relationship is established. |
| IOCR | IOCR | Communication relationships for periodic process data: the controller and the device exchange I and Q in accordance with this cycle. |
| DCP | DCP | Discovery and Basic Configuration Protocol, used to locate devices on the network, assign station names, and IP. |
| LLDP | LLDP | The Neighbor Discovery Protocol is used to mapping the relationships between adjacent ports of devices on a network. |
| I&M0 | I&M0 | Identification and Maintenance Data: Records identification information such as the equipment's manufacturer, model, and version. |
| Station Name | Station Name | The device's name on the network.TIA The station name assigned here must match the site name in the configuration tool; the substitution value is darra-IO Device-01. |
| IOPS | IOPS | input variable (VAR_INPUT) Availability: "GOOD" indicates that the data sent by the controller is available. |
| IOCS | IOCS | output variable (VAR_OUTPUT) acceptance ST; "GOOD" indicates that the controller has accepted the device's output variable (VAR_OUTPUT). |
| Process Data | Process Data | The I and Q data exchanged between the controller and the device in each cycle. For information on data input on the host system side, see Darra OPC UA Client SDK. |
| Input Area I | Input Area I | The data area that the controller sends to the device is read-only. Address I0.0 / IB0 / IW2 / ID4. |
| Output Zone Q | Output Area Q | The data area where the device sends data to the controller; writable. Address Q0.0 / QB0 / QW2 / QD4. |
| Cycle | Cycle | The interval between process data exchanges between the two parties is freely configurable, with a minimum of 1 ms. |
| Watchdog | Watchdog | Timeout monitoring: If periodic data does not arrive within the specified time, it is deemed a failure. |
| Diagnosis | Diagnostics | Equipment operating ST and fault information. First, check the local diagnostics, then read and write process data. |
| Module | Module | The function blocks assigned to devices in the engineering configuration determine which bytes make up the process data. |
| Bay | Slot | The location of the modules on the equipment; the engineering configuration organizes the modules by slot. |
| subslot | Subslot | A finer addressing unit within a slot, used to distinguish between submodules or ports. |
| Vendor identification | VendorID | Identify the equipment manufacturer; specific values are subject to the exported file GSDML . |
| Product Code | ProductCode | Classify equipment together with the manufacturer's identifier; refer to the exported file GSDML for specific values. |
| Consistency Level | Conformance Class | PROFINET categorizes devices into A, B, and C classes to describe their functional capabilities. |
| big-endian (network byte order) | Big-Endian | In process data, word and double word are ordered with the high byte first. |
| Evaluation cycle time | Evaluation Period | Free trial cycle time before activation; see the online trial window for details. |
| online Experience Window | Offline Experience Window | A total of 2 hours of trial time is available when the device is not activated and not connected to the internet; this time accumulates across reboots and is not reset. If the device is connected to the internet but not activated, the trial cycle time does not begin, and the user is prompted to activate the device immediately. |
| Configuration Tool | Configuration Tool | A tool for graphically configuring station names, network cards, slots, and process data, as well as for exporting GSDML and RUN configurations. |
| Runtime Configuration | Runtime Configuration | Configuration tool exports runtime settings that are loaded by the service. |
| Real-time SDK | Realtime SDK | Development kits in six languages that connect directly to local devices to read and write process data; no data is transmitted to the host when establishing a link. |
| Unique Link | Unique Connection | Only one real-time client is allowed at a time; a second instance will be rejected. |
| Activation Code | Activation Code | Enter the authorization code provided after purchase into the configuration tool to complete activation. |
| Individual Authorization | Personal License | This license is tied to a single computer and must be activated online; it has no expiration date. |
| Corporate Authorization | Enterprise License | Licenses activated based on the number of seats purchased have no expiration date. |
This table only explains what the terms mean in context; it does not include implementation details. When encountering a specific issue, select the corresponding troubleshooting item based on the symptoms: Site Name /ai/profinet-station-name.txt, Can't connect /ai/profinet-not-connecting.txt, Process data remains unchanged /ai/profinet-no-process-data.txt, the cycle did not meet expectations /ai/profinet-cycle-too-slow.txt,GSDML and TIA /ai/profinet-gsdml-import.txt, Evaluation cycle time and Authorization /ai/profinet-evaluation-window.txt. Machine-Readable Assessment Card for Overall Capabilities and Boundaries /ai/evaluate.json. For a complete overview of the price and experience window, see Frequently Asked Questions.