Release Notes
Darra Profinet Slave Version History: To find out what's new in PnS updates, browse the entries here in reverse chronological order by version number. Current installer 1.6.4, six languages SDK 1.6.3, and drivers included with installation 1.6.0.
Each release records only three things: additions, changes, and known issues. The installer and the SDK may be on different version numbers; see the version matrix.
1.6.4(2026-11-13)
Installer 1.6.4 / SDK 1.6.3 / Driver 1.6.0.
New
None.
Changes
- The pre-installation environment check has been updated to a three-state system:Visual C++ it now checks for two items—runtime libraries and network protocol components—and will no longer generate a false positive “System Missing” error when it cannot determine the status.
- Before performing an installation, the installer first verifies its own location and no longer retrieves a program with the same name from the current directory.
- The "Pending Restart" prompt now counts only this product's own entries, so the installation is no longer blocked by pending restart statuses from other software.
- Complete the exception handling logs so that, when a problem occurs, you can see the cause and location in the logs.
- Only the installer is being updated this time; the six languages remain SDK unchanged 1.6.3.
Known Issues
- Upgrading from an older version still means uninstalling the old version and restarting first, then installing the new one; see Frequently Asked Questions.
- You cannot change the site name or slot configuration while the service is running; you must stop the service first before making changes.
1.6.3(2026-10-31)
Installer and six languages SDK synced to 1.6.3 / drivers 1.6.0.
New
None.
Changes
- Uninstallation Cleanup Fix: Network component bindings are no longer left behind after uninstallation, so reinstallation is not affected.
- Log descriptions will be standardized to reflect the official external messaging, and diagnostic logs will no longer contain terminology used exclusively internally.
- Exception logging has been enhanced; all failure paths now include the cause and context.
Known Issues
- None.
1.6.2(2026-10-30)
Installer and six languages SDK synced to 1.6.2 / drivers 1.6.0.
New
None.
Changes
- Fixed the issue where error code 1053 (The service did not respond in time to a startup or control request) occurred when the service started; the service now starts normally.
Known Issues
- None.
1.6.1(2026-10-30)
Installer and six languages SDK synchronized to 1.6.1 / drivers 1.6.0.
New
None.
Changes
- The version number has been updated to 1.6.1.
- Driver remains unchanged 1.6.0 : This driver has been certified by Microsoft for hardware compatibility; not a single byte will be altered, and the same driver will continue to be used after the upgrade.
Known Issues
- None.
1.6.0(2026-10-29)
Installer and six languages SDK synced to 1.6.0 / drivers 1.6.0.
New
- The driver has been certified by Microsoft for hardware compatibility and does not require any additional trust settings when installed on Windows 10/11 x64 systems.
Changes
- The version number jumped to 1.6.0; the product and SDK lines were launched simultaneously.
Known Issues
- None.
1.5.1(2026-10-28)
The installer and six languages have been SDK synchronized to 1.5.1.
New
None.
Changes
- The version numbers of the six language packs and the installer are aligned, so the installed version SDK matches the version reported by the installer.
Known Issues
- None.
1.5.0(2026-10-24)
The installer, drivers, and the six-language SDK shipped in the same batch.
New
- Six programming languages SDK(C, C++, C#, Java, Python, and Rust) were officially released alongside the installation package.
- The Rust SDK has reached general availability.
Changes
- The configuration tool's workflow has been adjusted so that the configuration of station names, network cards, slots, and process data now follows the same path.
- The drivers included with this version have been certified by Microsoft for hardware compatibility.
Known Issues
- None.
1.4.0(2026-10-15)
New
None.
Changes
- SDK Package Content Cleanup: Examples and tests are no longer included in the release package; only the files actually needed during development are left in the package.
- The version numbers of the language packs match the version reported by the installer.
Known Issues
- None.
1.3.0(2026-10-11)
New
None.
Changes
- Since the registration and factory acceptance of the bundled binary files are imminent, verify the files against the registered values during installation.
- Version number: Jump to 1.3.0.
Known Issues
- None.
1.2.0(2026-09-25)
New
None.
Changes
- Unified diagnostic terminology: The configuration tool uses the same terminology as the status, error codes, and error messages it SDK reads.
- The network adapter list scan has been finalized; there are no longer any duplicate or missing entries on machines with multiple network adapters.
- The SDK constant values are aligned across all languages, so the same state yields the same value in all six languages.
Known Issues
- None.
1.1.0(2026-09-21)
New
None.
Changes
- Six languages have been consolidated SDK into a single, unified real-time session entry point; the old, scattered interfaces have been removed. The previous sample code from before 1.1 cannot be compiled directly and must be rewritten to use the new entry point.
- The criterion for determining a "true" Boolean value in process data has been changed from 「an integer byte that is not 0」 to a check of the least significant bit; a "true" value is indicated when the least significant bit is 1. Both read and write operations must be parsed according to this new criterion.
Known Issues
- This release contains a breaking change: there is no replacement with the same name in the old interface. Before upgrading, modify your code to use the new interface and then switch to the new package.
1.0.4(2026-09-20)
New
None.
Changes
- Shutdown Process Fix: The system no longer freezes during shutdown due to communication components not being fully released.
Known Issues
- None.
1.0.3(2026-09-18)
New
- Reasons for the wait (WaitReason) are visible: When you can't connect, you can see exactly where the process is stuck without having to guess.
Changes
- The periodic transmission path has been fixed, and process data transmission no longer stops during prolonged operation.
- Adjustments to the installer interface and prompts.
- Add a fallback path to the startup interface so that, even in the event of an exception, a clear result is returned rather than no response.
Known Issues
- None.
1.0.2(2026-09-17)
New
None.
Changes
- Version numbers are standardized across the entire site; the installer, drivers, and six-language versions all SDK report the same version number.
- Remove the simulated data path; use only actual process data at runtime.
Known Issues
- None.
1.0.1 and earlier
1.0.1 Changes to this version and earlier versions have not been recorded item by item on this site. All package downloads are strictly based onDownloadThe current version of the page is the official version; direct links are updated with each new release and do not retain historical versions.