Event
device.Events Subscribe to operational status events.
Each event is logged again when it is triggered Logged(with the severity level matching the source event), regardless of whether a corresponding event has been subscribed to. Subscribe Logged to receive messages in Chinese.
Feature Overview
| Category | Event | Note | Automatic Logging |
|---|---|---|---|
| Connect | device.Events.ConnectedChanged | Alternate between on and off in sync with the IO controller's cycle | ✓ |
| Operating State | device.Events.StateChanged | Changes in Operating State | ✓ |
| Runtime Error | device.Events.ErrorOccurred | Runtime Error | ✓ |
| Process Data Quality | device.Events.IoStatusChanged | Changes in the "non-GOOD" byte count | ✓ |
| Link | device.Events.LinkChanged | Changes in the Network Card's Physical Link | ✓ |
| Log | device.Events.Logged | Each event listed above will trigger this one again. | — |
Connect
ConnectedChanged
device.Events.ConnectedChanged += (sender, e) => { };
// EventHandler<PnSConnectedChangedEventArgs>
Triggered when the periodic data exchange connection is lost (Connected == false where EverConnected == true = disconnection; EverConnected == false = never connected).
Callback parameters:
public sealed class PnSConnectedChangedEventArgs : EventArgs
{
public bool Connected { get; } // Is the data currently being updated for a new cycle?
public bool EverConnected { get; } // Have you ever connected to it?
public PnSEventLevel Level { get; } // Connected = Info; Disconnected / Never Connected = Warn
}
Example:
device.Events.ConnectedChanged += (sender, e) =>
{
if (!e.Connected && e.EverConnected)
Console.WriteLine("掉线");
};
Operating State
StateChanged
device.Events.StateChanged += (sender, e) => { };
// EventHandler<PnSStateChangedEventArgs>
Triggered when the operating state changes (SDK observation only; does not actively switch states).
Callback parameters:
public sealed class PnSStateChangedEventArgs : EventArgs
{
public PnSState OldState { get; } // Before the change, see [PnSState](./api#pnsstate)
public PnSState NewState { get; } // After the change
public PnSEventLevel Level { get; } // Info
}
Example:
device.Events.StateChanged += (sender, e) =>
Console.WriteLine($"{e.OldState} → {e.NewState}");
ErrorOccurred
device.Events.ErrorOccurred += (sender, e) => { };
// EventHandler<PnSErrorEventArgs>
Triggered when a runtime error occurs; e.ErrorCode it is an int primitive value; for enumeration types, use device.ErrorCode.
Callback parameters:
public sealed class PnSErrorEventArgs : EventArgs
{
public int ErrorCode { get; } // Original value of a runtime error (not an enumeration)
public string Message { get; } // News in Chinese
public PnSEventLevel Level { get; } // Warn
}
Example:
device.Events.ErrorOccurred += (sender, e) =>
Console.WriteLine($"{e.ErrorCode}: {e.Message}");
IoStatusChanged
device.Events.IoStatusChanged += (sender, e) => { };
// EventHandler<PnSIoStatusChangedEventArgs>
The first time I read it, I IOPS only recorded the baseline—no callback. inputIopsHex If outputIopsHex both are missing, no fiction, no callback. A callback is triggered only when the byte count changes and is not a "GOOD" byte. The same rule applies across all six languages—a callback is not triggered on every read.
Callback parameters:
public sealed class PnSIoStatusChangedEventArgs : EventArgs
{
public int IopsBad { get; } // IOPS BAD Byte Count (0 = All GOOD)
public PnSEventLevel Level { get; } // BAD > 0 = Warn; otherwise, Info
}
Example:
device.Events.IoStatusChanged += (sender, e) =>
{
if (e.IopsBad > 0)
Console.WriteLine($"IOPS BAD: {e.IopsBad}");
};
LinkChanged
device.Events.LinkChanged += (sender, e) => { };
// EventHandler<PnSLinkChangedEventArgs>
Triggered when the physical link of the network card changes (during status polling, determined by the "LinkUp" field in the process data channel header; on the first observation, only the baseline is recorded, and no trigger occurs).
Callback parameters:
public sealed class PnSLinkChangedEventArgs : EventArgs
{
public bool LinkUp { get; } // Is the link up?
public PnSEventLevel Level { get; } // Up = Info; Down = Warn
}
Example:
device.Events.LinkChanged += (sender, e) =>
Console.WriteLine(e.LinkUp ? "链路 Up" : "链路 Down");
Log
Logged
public event Action<PnSEventLevel, string> Logged;
This message is sent again each time an event is triggered, and its severity level follows that of the source event.
Callback parameters:
level(PnSEventLevel) — Log Levelmessage(string) — Log body
PnSEventLevel Enumeration Values
Events and Log Levels.
public enum PnSEventLevel
{
Info = 0, // Information
Warn = 1, // Warning
Error = 2, // Error
}
Connection = Info, Disconnected / Run error = Warn.
Example:
device.Events.Logged += (PnSEventLevel level, string message) =>
Console.WriteLine($"[{level}] {message}");
Thread Safety
Event callbacks are not triggered on the UI thread. Thread synchronization is required when updating the user interface:
// WinForms
device.Events.ConnectedChanged += (sender, e) =>
this.Invoke(() => labelStatus.Text = e.Connected ? "已连接" : "未连接");
// WPF
device.Events.ConnectedChanged += (sender, e) =>
Dispatcher.Invoke(() => StatusText = e.Connected ? "已连接" : "未连接");
Events are dispatched asynchronously through the thread pool and are not called back synchronously on the observing thread. Each subscriber gets its own try/catch: if one subscriber throws, only that one callback is dropped, and later subscribers for the same event are not skipped. The failure count is observable through device.Events.EventsDropped (long, read-only).
To unsubscribe, use the built-in C# event -=. If you subscribe to the same delegate N times, you will receive N notifications, and it takes -= N subscriptions to completely unsubscribe.